304-Keyboard or System Unit Error
audible beeps: none
0
possible cause: keyboard, keyboard cable, mouse controller, or system board failure.
action:
1. be sure the keyboard and mouse are connected.
only authorized technicians trained by hp should attempt to remove the system board. if you
believe the system board requires replacement, contact hp technical support before proceeding.
2. run insight diagnostics ("hp insight diagnostics" on page 101) and replace failed components
as indicated.
400 series
list of messages:
40x-parallel port x address assignment conflict
404-parallel port address conflict detected
40x-parallel port x address assignment conflict
audible beeps: 2 short
possible cause: both external and internal ports are assigned to parallel port x.
action: run the server setup utility and correct the configuration.
404-parallel port address
...a hardware conflict in your system is keeping some system components from working
correctly. if you have recently added new hardware remove it to see if it is the cause of the conflict.
alternatively, use computer setup or your operating system to insure that no conflicts exist.
audible beeps: 2 short
possible cause: a hardware conflict in the system is preventing the parallel port from working
correctly.
action:
1. if you have recently added new hardware, remove it to see if the hardware is the cause of the
conflict.
the server setup utility to reassign resources for the parallel port and manually resolve the
resource conflict.
3. run insight diagnostics ("hp insight diagnostics" on page 101) and replace failed components
as indicated.
600 series
list of messages:
601-diskette controller error
602-diskette boot record error
605-diskette drive type error
611-primary floppy port address assignment conflict
612-secondary floppy port address assignment conflict
601-diskette controller error
audible beeps: none
possible cause: diskette controller circuitry failure occurred.
action:
1. be sure the diskette drive cables are connected.
2. replace the diskette drive, the cable, or both.
3. run insight diagnostics ("hp insight diagnostics" on page 101) and replace failed components
as indicated.
602-diskette boot record error
audible beeps: none
possible cause: the boot sector on the boot disk is corrupt.
action:
1. remove the diskette from the diskette drive.
2. replace the diskette in the drive.
3. reformat the diskette.
605-diskette drive type error.
audible beeps: 2 short
possible cause: mismatch in drive type occurred.
action: run the server setup utility to set the diskette drive type correctly.
611-primary floppy port address assignment conflict
audible beeps: 2 short
possible cause: a hardware conflict in the system is preventing the diskette drive from
版权声明:本文标题:[讲解]HP服务器的一些启动报错的原因和解决办法(中英双语) 内容由热心网友自发贡献,该文观点仅代表作者本人, 转载请联系作者并注明出处:https://m.elefans.com/dianzi/1715996958a480839.html, 本站仅提供信息存储空间服务,不拥有所有权,不承担相关法律责任。如发现本站有涉嫌抄袭侵权/违法违规的内容,一经查实,本站将立刻删除。