Quidway S1700-52R-2T2P-AC Ethernet Switch
User Manual & Installation Quick Start
快速安装指南以及简易使用说明书
Rev: 02
Quidway S1700-52R-2T2P-AC以太网交换机
Tool List
工具参考
Service and Support
技术支持
Crosshead screwdriver
十字螺丝刀
Flathead screwdriver
一字螺丝刀
Marker pen
记号笔
M6 Plug bolt
M6膨胀螺栓
Percussion drill(φ8 Drill bit)
冲击钻(φ8钻头)
Claw hammerAdjustable spannerESD-preventiveCable tieOptical fiber bundling tapeDiagonal pliers
羊角锤活动扳手防静电手套线扣光纤绑扎带斜口钳
Accessories (S1700-52R-2T2P-AC)
设备附件介绍(S1700-52R-2T2P-AC)
Rubber pads
胶垫贴
Captive nut
浮动螺母
M4 screw
M4
螺钉
M6 screw
M6
螺钉
Short rack-mounting ear
短挂耳
Precautions
注意事项
Before installation, take ESD-preventive measures, for example, wear ESD-preventive gloves or a wrist strap.
安装前请做好防静电保护措施,如配戴防静电手套或防静电手腕。
Installing the Device in a 19'' Cabinet
安装设备到19英寸标准机柜中
Fix the rack-mounting ears.
安装挂耳。
Install the device in a cabinet.
安装设备到机柜。
IEC cabinet (19 inch)
IEC机柜(19英寸)
Fix the captive nuts.
安装浮动螺母。
1U=44.45mm
1U
Use installation strip to fix the captive nuts.
使用安装条安装浮动螺母。
4
Installing the Device on a Worktable
安装设备到工作台
Adhibit the rubber pads.
粘贴胶垫贴。
Install the device on a worktable.
安装设备到工作台。
Rubber pads
胶垫贴
Installing the Device on a Wall
安装设备到墙面
●To prevent injuries, check that there is no electrical wire at the locations to be drilled before drilling holes in the wall.
●Flammable and explosive items under the device is prohibited. Leave more than 100 mm of space around the device for proper heat dissipation.
●
在墙上打孔时,必须确认打孔处没有墙电,避免造成人身伤害。
●
设备下方禁止摆放易燃易爆物品,距离设备100mm范围内不能有异物挡住。
Fix the rack-mounting ears.
安装挂耳。
Install the plug bolt.
安装膨胀螺栓。
φ8 Drill bit
φ8钻头
M6plug bolt
M6膨胀螺栓
90
。
Install the device on the wall.
安装设备到墙面。
Mark the hole locations on the wall according to
the device installed with rack-mounting ears.
根据已安装挂耳的设备,用记号笔标记打孔位置。
Installing the SFP Transceiver
SFP收发器的安装
Insert the transceiver with the optical connector
facing outward and the slot connector facing down.
插入SFP收发器,光纤连接口朝外,且插槽朝下。
Connect the LC connector to SFP transceiver.
将光纤的LC连接器连接到光模块上。
5
Connecting PGND Cables and Power Cables
连接保护地线和电源线
Connect the PGND cable.
连接地线。
Connect the AC power cable.
连接交流电源线。
● Do not connect power cables when the device is powered on, so as to avoid injuries.
● Do not power on the device before device installation and cabling are completed.
● Make sure that the protection grounding cable of the device is grounded.
● The S1700-52R-2T2P-AC can use only AC power supply.
● 严禁带电安装电源线,以免造成人身伤害。
● 严禁在设备安装和布线完成前向设备供电。
● 确定设备保护地线接地。
● S1700-52R-2T2P-AC只支持交流电源。
Laying out Cables
布放线缆
Optical fibers
光纤
Cable tie
线扣
Fiber bundling tape
光纤绑扎带
6
● Do not stare at optical interfaces. The optical fiber contains laser light sources that hurt human eyes.
● Lay out and bundle power cables, optical fibers, and Ethernet cables separately, with the distances in between longer than 10 cm.
● 不要直视光纤接口,光纤中的激光会伤害眼睛。
● 电源线与信号线缆的间距要大于10厘米。
During the cabling, if the quantity of cables is rather great, you can route the cables in the cabinet first, and then install connectors
to the cables.
布线时,如果线缆数目比较多,为了布线更方便,可以先不做线缆接头,先将线缆在机柜中布置好,再做与设备连接的线缆接头。
Powering on the System
上电检查
● Power on the device only when the input voltage is in the normal range. Test the AC input voltage for S1700-52R-2T2P-AC.
The voltage should range from 100 VAC to 240 VAC.
● After the device is powered on, the PWR LED is on. the port LED status is as shown in below.
● 测试S1700-52R-2T2P-AC的输入电压,若此电压在100-240V交流电正常范围内可将设备上电。
● 设备上电后,PWR电源指示灯亮,端口LED灯状态如下图所示。
1-48 Port LED
1-48 端口指示灯
GE1-GE4 Port LED
GE1-GE4 端口指示灯
PWR LED
电源指示灯
LED Indicator
LED状态
LED
PWR
Condition
状态
On Green
绿色常亮